Description
The MEMS series currently encompasses 11 different types of gas sensors HCHO, CO, CH4, VOC, NH3, H2S, EtOH, Smoke, Odor, H2, NO2
Precautions for use
- Kindly remove the protective film before usage.
- To prevent exposure to volatile silicon compounds vapors (such as silicone adhesive, hair gel, silicone rubber, or other locations where volatile silicon compounds are present).
- Avoid exposure to high concentrations of corrosive gases (such as H2S, SOX, Cl2, HCl, etc.).
- Prevent contamination from alkalis, alkali metal salts, and halogens.
- Refrain from prolonged exposure to extreme environments (such as high temperatures, high humidity, high pollution).
- Avoid contact with water, condensation, and freezing.
- Minimize excessive vibration, impact, and dropping.
- Please refrain from employing this module in systems that involve personal safety concerns.
- For extended periods of non-usage, it is advisable to preheat the module for at least 24 hours.
FEATURES
- Compact size, measuring only 13*13*2.5mm
- Low power consumption, operating current <20mA
- High sensitivity and rapid response recovery
- Advanced MEMS technology
APPLICATIONS
- Environmental monitoring: identify the sources and levels of benzene in the ambient air
- Indoor air quality: measure the concentration of formaldehyde in the indoor air
- Industrial safety: detect any leaks or spills of tetrachloroethylene
- Fire detection: detect the early signs of fire and smoke by sensing the changes in the composition and concentration of VOCs in the air.
- Health applications: measure the amount of acetone in the breath and provide feedback or guidance for diabetes management.
SPECIFICATION
- Gas detected: ethanol, formaldehyde, toluene, etc
- Detection range: 1-500ppm
- Operating voltage: 3.3-5V
- Operating current: <20mA
- Output signal: Analog voltage
- Sensitivity: R0(in air)/Rs(in 150ppm ethanol) ≥ 3
- Operating temperature: -10-50℃
- Operating humidity: 15-90%RH (non-condensing)
- Lifespan: ≥5 years (in air)